Studer Xtender XTS 1400-48 1200W / 1400W 12A 48VDC Inverter Charger

More Views

Studer Xtender XTS 1400-48 1200W / 1400W 12A 48VDC Inverter Charger

$1,709.00
Add Items to Cart
OR

Quick Overview

IP 54 Rating
Swiss Made
Incredibly Versatile
5 Year Warranty

Ideal for Industrial Applications

Product Description

The Xtender series provides unmatched freedom of use due to its many functions. In a basic application it offers a total package : the functions of inverter, battery charger, transfer system and assistance to the source. These functions can be combined and controlled in a totally automatic way for exceptional ease and optimal management of available energy.

The Xtender is equipped with a command entry and 2 configurable auxiliary contacts. This allows automatic control of a genset or a load shedding when the battery voltage is too low. This flexibility makes it possible to implement special functionalities necessary for a good energy management in standalone power systems.

 

Features

  • Outstanding efficiency and overload.
  • Perfect management and limitation of AC sources.
  • Power shaving of consumption peaks.
  • Active filtering of load steps on a genset.
  • Automatic protection of sources against overload.
  • Parallel and three-phase setting, up to 9 units (12.6kW).
  • Powerful multi-stage PFC charger.
  • Ultra-short transfer time (from 0 to 15ms max.)
  • Automatic and efficient stand-by
  • 2 programmable auxiliary contacts (optional on the XTS)
  • Compatible with AC coupling
  • XTS electronically protected against reverse polarity
  • Display, programming and data logging via optional remote control.
  • RS-232 communication for remote monitoring.

 

Specifications

Model XTS 1400-48
Nominal Battery Volage 48V DC
Rated Power Continuous 750VA / 900VA **
Rated Power 30min 1200VA / 1400VA **
Rated Power Surge 2800VA
Load Detection * (stand-by) 2 to 25W
Peak Efficiency 93%
Consumption (off/standby/on) 1.3W / 1.6W / 8W
Output Voltage * Pure Sine Wave 230VAC +/- 2%
Output Frequency * 50Hz +/- 0.05%
Harmonic Distortion < 2%
Overload & Short Circuit Protection Automatic Disconnect with 3 time restart attempt
Charge Characteristics * 6 Steps - Bulk / Absorption / Float / Equalisation / Reduced Float / Periodic Absorption
Max Charge Current * 12A
Temp. Compensation * With BTS-01 or BSP 500/1200
Input Voltage Range * 150 to 265Vac 
Input Frequency 45 to 65Hz
Max Output Current 20A
Transfer Time < 15ms
Protection Index IP 54
Operating Temp Range -20 to 55 °C
Weight 9.3kg
Dimensions 110 x 210 x 310 mm
Warranty 5 Years

* Adjustable with the remote RCC-02 / RCC-03

∗∗ These features are valid only when using the cooling module ECF-01.

Additional Information

Manufacturer Studer Innotech
 
All Prices are in AU$ and include GST